亚洲一区中文字幕-亚洲一区中文字幕在线-亚洲一区中文字幕在线观看-亚洲一区综合-亚洲一区综合在线播放-亚洲一一在线

Unipulse F701-C weighing controller with accumulation function

Unipulse F701-C weighing controller with accumulation functionF701-C is a general-purpose weighing controller that is compatible with all weighing systems. This is a practical device excellent in cost

  • Brand:: Unipulse
  • Model:: F701-C

Unipulse F701-C weighing controller with accumulation function

F701-C is a general-purpose weighing controller that is compatible with all weighing systems. This is a practical device excellent in cost effectiveness, which is equipped with the final discharge function allowing high-accuracy feeding and discharging weighing control and the weighing sequence function essential to hopper and packing scales. 
Installable is the interface that can be connected to PLCs or various peripherals such as BCD output, RS-232C and CC-Link.

選型F701-C.jpg

ANALOG SECTION
Excitation voltage10V DC ±5%, Output current; within 120mA (Up to 4 loadcells at 350Ω are parallel-connectable)
Zero adjustment range0 - 2mV/V
Rough adjustment: Digitally controlled via rough adjustment circuit
Fine adjustment: Auto adjusting method via digital processing
Gain adjustment range0.3 - 3.2mV/V
Rough adjustment: Digitally controlled via rough adjustment circuit
Fine adjustment: Auto adjusting method via digital processing
Min. input sensitivity0.3μV / count
AccuracyNon-linearity: within 0.01% FS 
Zero drift: within 0.2μV/°C RTI
Gain drift: within 15 ppm/°C
Analog filterBessel low-pass filter (-12dB/oct.), Selectable from 2, 4, 6, 8 Hz
A/D converterSpeed: 200 times/sec
Resolution: 24 bit (binary)
 
SETTING SECTION
Setting items- High limit, Low limit, near zero, SP1, SP2, Compensation, over, under, final
- Comparison inhibit time, judging time, complete output time, adjust feeding time, auto zero times, judging times. Auto free fall compensation regulation, analog filter, tare weight
- Weighing function 1, weighing function 2, weighing function 3, sequence mode, function key inhibit, digital filter, motion detect, zero tracking period, zero tracking range
- Balance weight value, capacity, min. scale division, net over, gross over, DZ regulation value, function selection, gravitation acceleration (area number input), gravitation acceleration (acceleration input)
- D/A output mode, D/A zero output weight, D/A full scale, RS-485 I/F, ID number, RS-232C I/F, external function selection, setting value LOCK, restriction on the tare subtraction function
- Input selection, output selection, CC-Link I/F Occupied station & Transmission speed, CC-Link I/F Station No.
- Average weight, maximum weight, minimum weight, population standard deviation, sample standard deviation, number of data (n), latest accumulation date, Maximum-minimum (R), option substrate
- Span calibration, equivalent input calibration, password input, zero calibration
 
INPUT/OUTPUT SECTION
External output signalTransistor’s open collector output (Emitter = COM terminal); Output is LO when transistor is ON. Near zero, SP1, SP2, SP3, under, over, Low limit, high limit, stable, weight alarm or error, go or complete, run or accumulation error
External input signal

ON when shorted to COM terminal by contact (relay, switch) or non contact (TTL-level transistor or open collector output) G/N, digital zero, tare subtraction ON, tare subtraction OFF, hold*, judge*, feed / discharge, start*, stop*, accumulation command*, accumulation clear*

*Signals for selection. Up to 4 can be selected.

Interface
  • SIF:

  • 2-wire type serial interface (standard); Interface to link with Unipulse printer or external display

  •  

  • 232:

  • RS-232C communication interface (standard): Write (change) / read weight data, various statuses and setting values by commands from a host computer

  •  

  • BCO:

  • BCD parallel data output interface (Optional): Parallel interface to transmit weight data to various peripherals

  •  

  • 485:

  • RS-485 communication interface (Optional): Allows longer-distance communication than RS-232C. ID numbers are set, and multiple units of F701-C are parallel-connectable.

  •  

  • DAC:

  • D/A converter interface (Optional); Interface to convert weight data to current signal and output it.

  •  

  • CCL:

  • CC-Link interface (Optional); Links directly to PLC.

 
DISPLAY SECTION
Display unitNumerical display (7 digits) with a character height of 10.4 mm by fluorescent display tube, Sub-display; character height 4.0 mm
Display value5 digits, Sign; Minus sign displayed on most significant digit
UnitSelectable from t, kg, g, N, lb, none
Status displaySP1, SP2, SP3, NEAR ZERO, HOLD, ZERO ALARM, STAB, TARE, NET, ZERO, BATTERY CONDITIONS
 
GENERAL SPECIFICATIONS
Power supply voltage100 - 240V AC (+10% - 15%) (Free power supply 50/60 Hz)
Power consumptionApprox. 15VA
Operating conditionsTemperature: Working temperature range -10 - +40°C; Storage temperature range -20 - +85°C
Humidity: 85% RH or less (non-condensing)
External dimensions144 (W) x 72 (H) x 160 (D) [mm] (protruding parts not included)
WeightApprox. 1.0 g
 
OPTION
BCOBCD parallel data output interface
485RS-485 communication interface
DACD/A converter interface
CCLCC-Link interface
Number of mountable options1
 
ACCESSORIES
AC input cord (nominal rating: 125V) 3m1
Mini-driver1
FCN series I/O connector (with cover)1
Jumper cable2
Operation Manual1
BCD output connector (when BCD output option is installed)1
RS-485 connector (when RS-485 option is installed)1
D/A converter connector (when D/A converter option is installed)1
CC-Link connector (when CC-Link option is installed)1
  
Drum Filling Machine

Option

ModelDescription
BCOBCD parallel data output interface
485RS-485 communication interface
DACD/A converter interface
CCLCC-Link interface
  
Drum Filling Machine

Optional accessories

ModelDescription
CAAC2P-B3AC Supply cord 3m
CAAC3P-CEE7/7-B2AC Supply cord (Voltage resistance:250V)2m
CN34D-Sub 9p connector for RS-232
CN50FCN series I/O connector (with cover)
CN55FCN series I/O connector (with diagonal cover)
CN70D/A converter connector
CN71RS-485?CC-Link connector
CN80Analog I/O connector terminal
F720 mounting panelMounting panel for F252 / F280 to F701-C conversion
LB01-XHLithium battery (with XH connector)


CONTACT US

Skype: fayfaywang1027

QQ: 429682794

Whatsapp: 008618016442021

E-mail: glzoncn@163.com

https://glzon.en.alibaba.com/

cel: +0086 18016442021

主站蜘蛛池模板: 国产成人综合一区人人 | 精品免费久久久久久影院 | 欧美三级网站 | 国产精品美乳免费看 | 国产欧美日韩亚洲精品区2345 | 久久男人精品 | 国产一区二区三区在线视频 | 浮力影院最新地址 | 亚洲综合在线成人一区 | 日韩经典在线观看 | 成人三级在线视频 | 91精品福利老司机在线观看 | 日本19禁啪啪无遮挡免费观看 | 色综合精品 | 国产精品视频久久久 | 免费观看成年的网站 | 亚洲综合色一区二区三区小说 | 99视频精品全部免费免费观 | 色婷婷久久免费网站 | 91天堂一区二区 | 久久大香萑太香蕉综合网 | 久久综合综合 | 日韩在线观看一区 | 亚洲综合第一欧美日韩中文 | 天天操综合网 | 国产大陆老老太老头性视频 | www.综合色| 亚洲成人在线视频网站 | 国产精品爱久久久久久久三级 | 97免费观看视频 | 欧美另类videossexo性 | 国产欧美日韩另类 | 亚洲精品一区二区三区四 | 在线小视频 | 久草大| 人人99| 中文有码在线 | 亚洲人成网站在线观看青青 | 91精品全国免费观看老司机 | 久久两性 | 精品久久久久久久久免费影院 |